T.S. 0
Drawing Number | Drawing | Drawing Name | Date |
---|---|---|---|
0-1 | Standard Abbreviations | May 2015 | |
0-2 (1/3) | Plan Symbols | January 2012 | |
0-2 (2/3) | Plan Symbols | January 2012 | |
0-2 (3/3) | Plan Symbols | January 2012 | |
0-3 (1/2) | Standard Definitions | March 2010 | |
0-3 (2/2) | Standard Definitions | March 2010 | |
0-4 | Reference Documents and General Requirements | November 2022 |
T.S. 1
Drawing Number | Drawing | Drawing Name | Date |
---|---|---|---|
1-1 (1/2) | Light Duty - Light Weight No. 5 and No. 7 Pull Box | September 2011 | |
1-1 (2/2) | Light Duty - Light Weight No. 5 and No. 7 Slope Wall Body Pull Box Details | September 2011 | |
1-2 | Heavy Duty No. 5 and No. 7 Straight Body Wall Pull Box Details | March 2015 | |
1-3 | Replacement Lid Sizing for Existing No. 5 and No. 7 Pull Boxes | September 2011 | |
1-4 (1/3) | Typical Pull Box Installation and Wiring Details | September 2011 | |
1-4 (2/3) | Typical Pull Box Installation and Wiring Details | September 2011 | |
1-4 (3/3) | Typical Pull Box Installation Details | September 2011 | |
1-5 (1/2) | Electrical Conduit Cover and Trench Requirements | September 2011 | |
1-5 (2/2) | Conduit Expansion Couplings | September 2011 | |
1-6 | Conductor Requirements | September 2011 | |
1-7 | Traffic Signal IMSA Cable Color Codes | March 2010 | |
1-8 (1/2) | Front of Barrier Junction Box | September 2011 | |
1-8 (2/2) | Back of Barrier Junction Box | September 2011 | |
1-9 | Top of Barrier Junction Box Details | September 2011 | |
1-10 | Top of Barrier Junction Box Details | September 2011 | |
1-11 (1/3) | Heavy Duty Lighting No. 4 and No. 6 Pull Box | October 2013 | |
1-11 (2/3) | Heavy Duty Lighting No. 4 and No. 6 Pull Box | October 2013 | |
1-11 (3/3) | Heavy Duty Lighting No. 4 and No. 6 Pull Box Lid | March 2015 | |
1-12 (1-2) | Precast Heavy Duty Lighting No. 4B and No. 6B Pull Box | March 2015 | |
1-12 (2-2) | Precast Heavy Duty Lighting No. 4B and 6B Pull Box | March 2015 |
T.S. 2
Drawing Number | Drawing | Drawing Name | Date |
---|---|---|---|
2-1 | Foundation for Type II Load Center Cabinet | March 2010 | |
2-2 | Foundation for Type IV Load Center Cabinet | March 2010 | |
2-3 | Foundation for Type III Control Cabinet | March 2010 | |
2-4 | Foundation for Type IV, V Control Cabinets | March 2010 | |
2-5 | Type A Foundation for 340 Controller Cabinets | March 2010 | |
2-6 | Meter Pedestal Cabinet Foundation and Base | March 2010 | |
2-7 | Traffic Signal UPS Cabinet Foundation Detail | March 2015 |
T.S. 3
Drawing Number | Drawing | Drawing Name | Date |
---|---|---|---|
3-0 | Notes for Type II and IV Load Center Cabinets | December 2012 | |
3-1 | Type II Load Center Cabinet | March 2010 | |
3-2 | Type IV Load Center Cabinet | March 2010 | |
3-3 | Type II Load Center Cabinet Wiring Details 240/480 3W /Disconnect | March 2010 | |
3-4 (1/2) | Photo Electric Cell Mounting Details | March 2010 | |
3-4 (2/2) | Photo Electric Cell Mounting Details | March 2010 | |
3-5 (1/2) | Type I and II Meter Pedestal Cabinet | March 2010 | |
3-5 (2/2) | Meter Pedestal Cabinet | December 2012 | |
3-6 | Type III Control Cabinet | March 2010 | |
3-7 | Pole Mount for Type III Control Cabinet | March 2010 | |
3-8 (1/2) | Pole Mount Details for Type III Control Cabinet | March 2010 | |
3-8 (2/2) | Pole Mount Details for Type III Control Cabinet | March 2010 | |
3-9 (1/3) | Type IV and V Control Cabinet Notes | March 2010 | |
3-9 (2/3) | Type IV Control Cabinet | March 2010 | |
3-9 (3/3) | Type V Control Cabinet | March 2010 | |
3-10 | Cabinet Extension Elevator Base | March 2010 | |
3-11 | Control Cabinet Mounted Service Enclosure | March 2010 | |
3-12 (1/2) | 120/240 or 240/480 Volt, Single Phase Utility Pull Section and Service Disconnect Details | March 2010 | |
3-12 (2/2) | 120/240 or 240/480 Volt, Single Phase Utility Pull Section and Service Disconnect Details | March 2010 | |
3-13 (1/3) | Traffic Signals & Lighting Model 345 Cabinet Details | March 2010 | |
3-13 (2/3) | Traffic Signals & Lighting Model 345 Cabinet Details | March 2010 | |
3-13 (3/3) | Traffic Signals & Lighting Model 345 Cabinet Cage Detail | March 2010 |
T.SL. 4
Drawing Number | Drawing | Drawing Name | Date |
---|---|---|---|
4-1 | Type "A" Pole | November 2022 | |
4-2 | Type "S" Pole | November 2022 | |
4-3 | Type "T" Pole | November 2022 | |
4-4 | Type "S" and "T" Steel Twin Luminaire Mounting Bracket and Extensions | November 2022 | |
4-5 | Aluminum Type "S" Pole | November 2022 | |
4-6 | Aluminum Type "T" Pole | November 2022 | |
4-7 | Type "G" Pole | November 2022 | |
4-8 | Aluminum Type "G" Pole | November 2022 | |
4-9 | Aluminum Type "H" Pole | November 2022 | |
4-10 | Aluminum Type "I" Pole | November 2022 | |
4-11 | General Notes for Traffic Signal and Lighting Poles with Maximum Loading Case | November 2022 | |
4-12 | Type "J" Poles (25-J, 30-J, 35-J, and 40-J) With 25 ft to 40 ft Mast Arm Span Length | April 2019 | |
4-13 | Type "Q" Poles (25-QL, 30-QL, 35-QL, and 40-QL) with 25 ft to 40 ft Mast Arm Span Length with Luminaire | April 2019 | |
4-14 | Type "K" Poles (45-K, 50-K, and 55-K) with 45 ft to 55 ft Mast Arm Span Length | April 2019 | |
4-15 | Type "R" Poles (45-RL, 50-RL, and 5-RL) with 45 ft to 55 ft Mast Arm Span Length With Luminaire | April 2019 | |
4-16 | Type "V" Poles (60-V and 65-V) with 60 ft to 65 ft Mast Arm Span Length | November 2022 | |
4-17 | Type "W" Poles (60-WL and 65-WL) with 60 ft to 65 ft Mast Arm Span Length With Luminaire | November 2022 | |
4-18 | Pole Hand Hole Details | November 2022 | |
4-19 | Type "U" Pole (Elliptical Base) Details | November 2022 | |
4-20 | Type "U" Pole (Round Pole with Square Base) Notes | November 2022 | |
4-21 | Type "U" Pole (Round Pole with Square Base) Foundation Details | April 2019 | |
4-22 | Type "U" Pole (Round Pole with Square Base) Detail 1 | April 2019 | |
4-23 | Type "U" Pole (Round Pole with Square Base) Detail 2 | April 2019 | |
4-24 | Type "U" Pole (Round Pole with Square Base) Pipe Tenon Details | April 2019 | |
4-25 | Type "U" Pole (Round Pole with Square Base) Twin Luminaire Mounting Bracket Details | April 2019 | |
4-26 | Equipment Mounting Height Details | April 2019 | |
4-27 | Pedestrian Push Button Post "Type PB Pole" | April 2019 | |
4-28 | Pole Foundation Anchor Bolts | November 2022 | |
4-29 | Steel Mast Arm Details Luminaire and Signal Arms to 20' | April 2019 | |
4-30 | Aluminum Truss Arm Details Type G, H, and I Poles | April 2019 | |
4-31 | Signal Mast Arm Tenon Details | April 2019 | |
4-32 | Typical Highway Lighting Offsets in Cut and Fill Sections | April 2019 | |
4-33 | Steel Adapter Plate for 30 Ft Aluminum Type "G" or Type "S" Light Poles | November 2022 |
T.S. 5
Drawing Number | Drawing | Drawing Name | Date |
---|---|---|---|
5-0 | Type 2 and 3 Cast Aluminum Break-Away Bases | April 2019 | |
5-1 | Type 2 Cast Aluminum Break-Away Base | April 2019 | |
5-2 | Type 3 Cast Aluminum Break-Away Base | April 2019 | |
5-3 | Installation Details for Pole Foundations with Type 2 and 3 Break-Away Bases | April 2019 |
T.S. 6
Drawing Number | Drawing | Drawing Name | Date |
---|---|---|---|
6-1 | Type C Vehicle Detector Loops for Traffic Counters | March 2010 | |
6-2 (1/3) | Type SA and SB Speed/Vehicle Classification Systems | March 2010 | |
6-2 (2/3) | Type SA Speed/Vehicle Classification Systems | March 2010 | |
6-2 (3/3) | Type SB Speed/Vehicle Classification Systems | March 2010 | |
6-3 | Piezoelectric Weight Sensor and Loop Lane Layout | December 2012 | |
6-4 (1/5) | Detector Loops and Piezoelectric Sensor Details | December 2012 | |
6-4 (2/5) | Detector Loops and Piezoelectric Sensor Details | December 2012 | |
6-4 (3/5) | Detail A Piezoelectric Sensor Details | March 2015 | |
6-4 (4/5) | Detail B Detector Loop Details | December 2012 | |
6-4 (5/5) | Detector Loops and Piezoelectric Sensor Details | December 2012 | |
6-5 | Microloops for Speed/Vehicle Classification | March 2010 | |
6-6 | Quartz Piezoelectric Weight Sensor and Loop Lane Layout | March 2010 | |
6-7 | Traffic Data Collection Cabinet Installation Details | March 2010 | |
6-8 | Type MPD Cabinet Pole, Base and Foundation Installation Details | March 2010 |
T.S. 7
Drawing Number | Drawing | Drawing Name | Date |
---|---|---|---|
7-1 (1/5) | Loop Detector Location Sawcut Patterns and Installation Details | March 2010 | |
7-1 (2/5) | Saw Cut and Coring Details | March 2010 | |
7-1 (3/5) | Saw Cut and Coring Details | March 2015 | |
7-1 (4/5) | Typical Detector Loop Lead-In Road to Pull Box Detail | March 2010 | |
7-1 (5/5) | Loop Detector Location and Installation Details | March 2010 | |
7-2 | Pre-Formed Loop Detectors for Ramp Metering and Counting | March 2010 | |
7-3 | Pre-Formed Loop Detectors in Bridge Deck | March 2010 | |
7-4 | Pre-Formed Loop Detectors in PCCP | March 2010 | |
7-5 | Typical Pre-Formed Loop Detector Stub-Out Detail | March 2010 |
T.S. 8
Drawing Number | Drawing | Drawing Name | Date |
---|---|---|---|
8-0 | Traffic Signal Vehicle Face Assembly Requirements and Details | December 2023 | |
8-1 | Vehicle Traffic Signal Face Assembly | December 2023 | |
8-2 | Vehicle Traffic Signal Face Assembly | December 2023 | |
8-4 (1/4) | 12-Inch Vehicle Traffic Signal Housing/Section | October 2013 | |
8-4 (2/4) | 12-Inch Vehicle Traffic Signal Housing/Section Notes | January 2012 | |
8-4 (3/4) | Vehicle Traffic Signal Housing/Section Details | January 2012 | |
8-4 (4/4) | Visors for 8-Inch and 12-Inch Vehicle Traffic Signal Face Assemblies | March 2010 | |
8-5 | Flashing Beacon Signal Face Assembly | January 2012 | |
8-6 | LED Lamp for Programmed Visibility Signal | January 2012 | |
8-7 (1/3) | Pedestrian Signal Assembly Requirements and Details | January 2012 | |
8-7 (2/3) | Pedestrian Signal Assembly Housing | January 2012 | |
8-7 (3/3) | Pedestrian Signal Assembly Visor | January 2012 |
T.S. 9
Drawing Number | Drawing | Drawing Name | Date |
---|---|---|---|
9-0 (1/2) | Mounting Assembly General Requirements | March 2010 | |
9-0 (2/2) | Mounting Assembly General Requirements | March 2010 | |
9-1 | Type I and II Mounting Assemblies | March 2010 | |
9-2 | Type III and IV Mounting Assemblies | March 2010 | |
9-3 | Type V Mounting Assembly | October 2013 | |
9-4 | Type VI Mounting Assembly | March 2010 | |
9-5 | Type VII Mounting Assembly | March 2010 | |
9-6 | Type VIII Mounting Assembly | March 2010 | |
9-7 | Type IX Mounting Assembly | March 2010 | |
9-8 | Type X Mounting Assembly | March 2010 | |
9-9 | Type XI Mounting Assembly | March 2010 |
T.S. 10
Drawing Number | Drawing | Drawing Name | Date |
---|---|---|---|
10-1 | Miscellaneous Signal Mounting Parts | March 2010 | |
10-2 | Mast Arm Signal Plumbizer | March 2010 | |
10-3 | Signal Mounting Pole Plate Details | March 2010 | |
10-4 | Terminal Compartment, Side Mounted and Pole Top Mounted | March 2010 |
T.S. 11
Drawing Number | Drawing | Drawing Name | Date |
---|---|---|---|
11-1 | Type I Pedestrian Push Button Housing Assembly | March 2015 | |
11-2 | Can Style Pedestrian Push Button | March 2015 |
T.S. 12
Drawing Number | Drawing | Drawing Name | Date |
---|---|---|---|
12-1 (1/3) | Advance Warning Flasher Pole Detail | March 2010 | |
12-1 (2/3) | Advance Warning Flasher Pole Sign Mounting Details | March 2010 | |
12-1 (3/3) | Advance Warning Flasher Pole Detail | March 2010 |
T.S. 13
Drawing Number | Drawing | Drawing Name | Date |
---|---|---|---|
13-1 | Sign Lighting Detail for Tubular Sign Structures | March 2010 | |
13-2 | Fuse Panel Details for Sign Lighting | March 2010 | |
13-3 | Placement of Lighting Fixtures for Overhead Signs | March 2015 |
T.S. 14
Drawing Number | Drawing | Drawing Name | Date |
---|---|---|---|
14-1 (1/3) | High Pressure Sodium (HPS) Lamps | March 2010 | |
14-1 (2/3) | High Pressure Sodium (HPS) Lamps | March 2010 | |
14-1 (3/3) | High Pressure Sodium (HPS) Lamps | March 2010 | |
14-2 | Pedestrian Bridge Lighting Details | March 2010 |
T.S. 15
Drawing Number | Drawing | Drawing Name | Date |
---|---|---|---|
15-0 (1/3) | General Notes | April 2019 | |
15-0 (2/3) | General Notes | April 2019 | |
15-0 (3/3) | General Notes | April 2019 | |
15-1 (1/6) | Steel Pole Typical Details | April 2019 | |
15-1 (2/6) | Steel Pole Foundation Details | April 2019 | |
15-1 (3/6) | Steel Pole Attachment Details | April 2019 | |
15-1 (4/6) | Wood Pole Typical Details | April 2019 | |
15-1 (5/6) | Wood Pole Typical Details | April 2019 | |
15-1 (6/6) | Typical Details | April 2019 | |
15-2 | Hanger and Balance Adjuster Typical Details | January 2012 | |
15-3 (1/3) | Signal Assembly Details | January 2012 | |
15-3 (2/3) | Conductor Entrance Heads Type A, B, and C | January 2012 | |
15-3 (3/3) | Aluminum Pipe Extension and Typical Details | January 2012 | |
15-4 (1/3) | Adjustable Sign Hanger Typical Details | January 2012 | |
15-4 (2/3) | Adjustable Sign Hanger Typical Details | January 2012 | |
15-4 (3/3) | Adjustable Sign Hanger Typical Details | January 2012 | |
15-5 | Adjustable Hanger Top and Extension Details | January 2012 | |
15-6 | Signal Tether Clamp Typical Details | January 2012 | |
15-7 | Pole Band Typical Details | January 2012 | |
15-8 | Weatherhead Typical Details | January 2012 |